Pressure amplifier RS-485 communication module load cell transducer DL-101

$ 13.04

Availability: 18 in stock
  • Type: RF Amplifier
  • Condition: New
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Model: 12
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back
  • Item must be returned within: 30 Days

    Description

    Pressure amplifier RS-485 communication module load cell transducer DL-101
    DL101 Description:
    Supermicro small volume : 28mm × 28mm, diameter 30mm, thickness of less than 4mm;
    Ultra-thin design : easy to common sensor adapted for digital sensors ;
    A / D Selection: 24 Δ-Σ;
    Valid data bits : 18 @ 10SPS;
    Temperature drift : <10PPM /
    Data rate : 5-40 times / sec ;
    Maximum output : ± 1040000;
    Signal range : ± 19mV, differential mode ;
    Load capacity: an impedance of not less than 350 ohm bridge sensors
    Communication : RS485, half duplex ;
    Communication speed: 2400,4800,9600 ( default ), 19200,38400,57600bps,
    The maximum number of networking : 32 ( can be increased by modifying the protocol to 200 or more) ;
    Supply voltage : 6-12V DC ( recommended voltage : 9V);
    Operating Current : ≤12mA ( not including sensors)
    Operating temperature range : -20 ~ 60
    Scope: 1 ) the digital transformation of resistance strain gauge load sensor ;
    2) AD -dispersed data collection ;
    3) No need to bridge sensor signals into digital signals occasion .
    Instruction Set Description:
    1 , sensor readings word
    2, set the module number
    3 , the module zeroed
    4, the full value of the module calibration
    5, the module returns data
    -------- 1-5 command all compatible command protocol compatible with the DL100
    6 , baud rate setting
    7 , any weight load calibration
    8, AD sampling rate settings
    9, AD filter depth settings
    10 , set the module continuous transmission
    11 , set the module sends the data delay
    12 , set the scale value and zero tracking
    13 , set the boot set to zero and the decimal point
    14 . Module initialization
    -- -- -- -- 6 to 13 instructions for the new instruction set
    -- -- new instruction analysis:
    9, the baud rate setting: the new command will make the model of arbitrary set an appropriate rate in support of the baud rate, to suit different applications;
    10, setting module continuous transmission: in a one to one correspondence, only the upper machine sent once this command, AD module can automatically results automatically sent to the host computer, convenient PC operation (this command to shut down after the invalid);
    11, setting module sends the data delay: delay parameter set free, can satisfy some slow PC contradiction in speed, ensure the return data will not be lost;
    12, 13, set the index value and zero followed, set the zero and decimal point: can make the module has a simple instrument function, realize the basic weighing function, and not just as a AD conversion module.
    14, the module initialization: recovery module all parameters to factory value.